Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Korean Journal of Radiology ; : 410-416, 2018.
Article in English | WPRIM | ID: wpr-715451

ABSTRACT

OBJECTIVE: To report the results of angioplasty with paclitaxel-coated balloons for the treatment of early restenosis of central veins in hemodialysis patients. MATERIALS AND METHODS: Sixteen patients (9 men and 7 women; mean age 65.8 ± 14.4 years; range, 40–82 years) with 16 episodes of early restenoses of central veins within 3 months (median patency duration 2.5 months) were enrolled from January 2014 to June 2015. Ten native central veins and 6 intra-stent central veins were treated with double paclitaxel-coated balloons (diameter 6–7 mm) plus a high pressure balloon (diameter 12–14 mm). The study outcomes included procedural success (< 30% residual stenosis) and primary patency of the treated lesion (< 50% angiographic stenosis without re-intervention). RESULTS: Procedural success was achieved in all 16 cases of central vein stenoses. The mean diameter of the central vein was 3.7 ± 2.4 mm before the procedure vs. 11.4 ± 1.8 mm after the initial procedure. There were no procedure-related complications. The mean diameters of the central veins at 6 months and 12 months were 7.8 ± 1.3 mm and 6.9 ± 2.7 mm, respectively. The primary patency rates at 6 months and 12 months were 93.8% and 31.2%, respectively. One patient had significant restenosis of the central vein at 3 months. The median primary patency period was 9 months for paclitaxel-coated balloons and 2.5 months for the last previous procedure with conventional balloons (p < 0.001). CONCLUSION: In our limited study, paclitaxel-coated balloons seem to improve the patency rate in cases of early restenosis of central veins. However, a further randomized control trial is necessary.


Subject(s)
Female , Humans , Male , Angioplasty , Angioplasty, Balloon , Constriction, Pathologic , Renal Dialysis , Veins
2.
J. vasc. bras ; 16(4): 276-284, out.-dez. 2017. tab, graf
Article in English | LILACS | ID: biblio-954676

ABSTRACT

Abstract Background Endovascular management of atherosclerotic infrainguinal arteries recently shifted towards drug eluting devices, designed to locally prevent the restenosis process. Numerous clinical studies report an advantage of drug coated balloons over uncoated balloon angioplasty in treating lower extremity peripheral artery disease. However, as coating and balloon platforms are different, each device requires dedicated clinical evaluations. Objective The aim of the study is to further investigate the safety and effectiveness of a Paclitaxel-Coated Balloon for the treatment of atherosclerotic infrainguinal arteries in a real-world setting. Methods 203 patients out of a final sample of 882 were enrolled in this prospective multicenter, observational, all-comers registry during the first 12 months. The primary endpoints were major adverse events (defined as procedure or device related death within 30 days post index procedure, clinically-driven target lesion revascularization or major target limb amputation) at 6 months and freedom from clinically-driven target lesion revascularization at 12 months. Both endpoints were adjudicated by a Clinical Events Committee. Results Mean patient age was 70.2±10.4 years (60.1% male). 47.3% of the patients were diabetic and 67.5% had a history of smoking. Severe claudication was reported in 37.4% and 40% had critical limb ischemia. 257 lesions, including 13.2% in the infrapopliteal territory, were treated with Passeo-18 Lux (mean lesion length 75.1 mm±69.4, 20% occlusions, 76.3% calcified). At 6 months, the rate of major adverse events was 5.5% (95%CI 3.1-9.7). Freedom from clinically-driven target lesion revascularization at 12 months was 93.2% (95%CI 89.1-95.8). All causes mortality was 6.5% (95%CI 3.8-11.0) and overall amputation rate was 4.2% (95%CI 2.1-8.3) at 12 months. Conclusion In a real-world environment, the BIOLUX P-III registry preliminary results confirm the safety and efficacy of the Paclitaxel-Coated Passeo-18 Lux balloon as a stand-alone treatment option for atherosclerotic infrainguinal arteries.


Resumo Contexto O manejo endovascular de artérias infrainguinais ateroscleróticas recentemente tem mudado para dispositivos farmacológicos, desenhados para impedir localmente o processo de reestenose. Numerosos estudos clínicos descrevem uma vantagem da angioplastia com uso de balões farmacológicos sobre os balões convencionais no tratamento de doença arterial periférica dos membros inferiores. No entanto, considerando que as plataformas do revestimento farmacológico e dos balões são diferentes, cada dispositivo requer avaliações clínicas específicas. Objetivo Fazer investigação adicional sobre a segurança e eficácia de um balão revestido com paclitaxel para o tratamento de artérias infrainguinais ateroscleróticas em um cenário de mundo real. Métodos 203 pacientes de uma amostra final de 882 pacientes foram incluídos neste registro prospectivo observacional multicêntrico de inclusão sequencial, durante os primeiros 12 meses. Os desfechos primários foram eventos adversos maiores (definidos como morte relacionada ao procedimento ou ao dispositivo em até 30 dias após o procedimento-índice, necessidade de revascularização da lesão-alvo ou amputação significativa do membro-alvo) em 6 meses e ausência de de revascularização da lesão-alvo em 12 meses. Ambos os desfechos foram adjudicados por um comitê de eventos clínicos. Resultados A idade média foi 70,2±10,4 anos (60,1% sexo masculino). 47,3% dos pacientes eram diabéticos, e 67,5% tinham história de tabagismo. Claudicação severa foi relatada em 37,4%, e 40% apresentava isquemia crítica de membro. 257 lesões, incluindo 13,2% em território infrapoplíteo, foram tratadas com o balão Passeo-18 Lux (comprimento médio das lesões 75,1 mm±69,4, 20% oclusões, 76,3% calcificadas). Aos 6 meses, a taxa de eventos adversos maiores foi de 5,5% (95%CI 3,1-9,7). A ausência de revascularização da lesão-alvo aos 12 meses foi de 93,2% (95%CI 89,1-95,8). Mortalidade por todas as causas foi de 6,5% (95%CI 3,8-11,0) e a taxa geral de amputação foi de 4,2% (95%CI 2,1-8,3) aos 12 meses. Conclusão Em um cenário de mundo real, os resultados preliminares do registro BIOLUX P-III confirmam a segurança e eficácia do balão revestido com paclitaxel Passeo-18 Lux como opção de tratamento único para artérias infrainguinais ateroscleróticas.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Paclitaxel/therapeutic use , Angioplasty, Balloon/instrumentation , Prospective Studies , Peripheral Arterial Disease/surgery , Endovascular Procedures
3.
Yonsei Medical Journal ; : 99-104, 2017.
Article in English | WPRIM | ID: wpr-65057

ABSTRACT

PURPOSE: This study compared the impact of paclitaxel-coated balloons (PCB) or drug eluting stents (DES) on peri-procedural myocardial infarction (PMI) on de novo coronary lesion in stable patients. MATERIALS AND METHODS: In this observational study, we compared the incidence of PMI amongst patients with single vessel de novo coronary lesions who underwent treatment with a PCB or DES. Propensity score-matching analysis was used to assemble a cohort of patients with similar baseline characteristics. PMI was classified as myocardial infarction occurring within 48 hours after percutaneous coronary intervention with a threshold of 5 x the 99th percentile upper reference limit of normal for creatine kinase-myocardial band (CK-MB) or troponin T (TnT). RESULTS: One hundred four patients (52 receiving PCB and 52 receiving DES) were enrolled in this study. The peak mean values of CK-MB and TnT were significantly higher in the DES group. There was a significantly higher rate of PMI in the DES group (23.1% vs. 1.9%, p=0.002). Total occlusion of the side-branch occurred in two patients treated with DES, while no patients treated with PCB. In multivariable analysis, DES was the only independent predictor of PMI compared with PCB (odds ratio 42.85, 95% confidence interval: 3.44–533.87, p=0.004). CONCLUSION: Treatment with a PCB on de novo coronary lesion might be associated with a significant reduction in the risk of PMI compared to DES.


Subject(s)
Aged , Female , Humans , Middle Aged , Creatine Kinase, MB Form/analysis , Drug-Eluting Stents , Incidence , Kaplan-Meier Estimate , Myocardial Infarction/enzymology , Odds Ratio , Paclitaxel/therapeutic use , Percutaneous Coronary Intervention/adverse effects , Propensity Score , Time Factors , Treatment Outcome
4.
Yonsei Medical Journal ; : 337-341, 2016.
Article in English | WPRIM | ID: wpr-147357

ABSTRACT

PURPOSE: This study compared the angiographic outcomes of paclitaxel-coated balloon (PCB) versus plain old balloon angioplasty (POBA) treatment for de novo coronary artery lesions. At present, there is no available data comparing the efficacy of PCB versus POBA for the treatment of de novo coronary lesions. MATERIALS AND METHODS: This multicenter retrospective observational study enrolled patients with de novo coronary lesions with a reference vessel diameter between 2.5 mm and 3.0 mm and lesion length or =50%) in POBA, compared to PCB (30.4%, n=7 vs. 4.1%, n=2, p<0.001). Target vessel revascularization was higher in the POBA group (13.0%, n=3 vs. 0%, p=0.033). CONCLUSION: PCB treatment of de novo coronary lesions showed better 9-month angiographic outcomes than POBA treatment alone.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary/instrumentation , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Stenosis/therapy , Coronary Vessels/pathology , Follow-Up Studies , Paclitaxel/administration & dosage , Retrospective Studies
5.
Yonsei Medical Journal ; : 606-613, 2016.
Article in English | WPRIM | ID: wpr-52540

ABSTRACT

PURPOSE: The effects on the side-branch (SB) ostium, following paclitaxel-coated balloon (PCB) treatment of de novo coronary lesions of main vessels have not been previously investigated. This study was aimed at evaluating the serial morphological changes of the SB ostium after PCB treatment of de novo coronary lesions of main vessels using optical coherence tomography (OCT). MATERIALS AND METHODS: This prospective, single-center observational study enrolled patients with de novo lesions, which were traversed by at least one SB (≥1.5 mm) and were treated with PCB. The SB ostium was evaluated with serial angiographic and OCT assessments pre- and post-procedure, and at 9-months follow-up. RESULTS: Sixteen main vessel lesions were successfully treated with PCB, and 26 SBs were included for analysis. Mean SB ostial lumen area increased at 9-months follow-up (0.92±0.68 mm2 pre-procedure, 1.03±0.77 mm2 post-procedure and 1.42±1.18 mm2 at 9-months). The SB ostial lumen area gain was 0.02±0.24 mm2 between pre- and post-procedure, 0.37±0.64 mm2 between post-procedure and 9-months, and 0.60±0.93 mm2 between pre-procedure and 9-months. The ostial lumen area increased by 3.9% [interquartile range (IQR) of -33.3 to 10.4%] between pre- and post-procedure, 52.1% (IQR of -0.7 to 77.3%) between post-procedure and 9-months and 76.1% (IQR of 18.2 to 86.6%) between pre-procedure and 9-months. CONCLUSION: PCB treatment of de novo coronary lesions of main vessels resulted in an increase in the SB ostial lumen area at 9-months.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary/methods , Coronary Angiography , Coronary Stenosis/diagnosis , Coronary Vessels/pathology , Drug-Eluting Stents/adverse effects , Paclitaxel/administration & dosage , Prospective Studies , Tomography, Optical Coherence/methods , Treatment Outcome , Tubulin Modulators/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL